612729
OPERATOR’S MANUAL
RELEASED: 12-1-64
REVISED:
(REV. F)
INCLUDING: SERVICE KITS, GENERAL DESCRIPTION & TROUBLESHOOTING
ALSO INCLUDE MANUALS: 662420-B BASIC PUMP MANUAL (PN 97999-108)
& S-632 GENERAL INFORMATION (PN 97999-624).
1-18-11
4-1/4” AIR MOTOR
OIL SUPPLY PUMP
9:1 RATIO
STUB
4” STROKE
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,
OPERATING OR SERVICING THIS EQUIPMENT.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.
1
SERVICE KITS
• 61268 for repair of Air Motor section.
• 61053 for repair of entire pump.
• 65823 for repair of Base Packing.
• Use only genuine AROR replacement parts to assure compatible
pressure rating and longest service life.
4
GENERAL DESCRIPTION
8
This model is designed for high volume delivery of low viscosity fluids
5
from standard containers. The model covered by this manual includes
an outlet swivel, material supply hoses and airline lubricator. Material
dispensing accessories and supply lines and fittings must be capable of
withstanding pressures developed by the pump.
7
6
• TheAROR9:1ratiobasicpumpassemblyconsistsof4-1/4”airmo-
tor and two ball lower pump end.
PUMP RATIO X
MAXIMUM PUMP
FLUID PRESSURE
=
INLET PRESSURE TO PUMP MOTOR
Pump ratio is an expression of the relationship between the pump motor area and
the lower pump end area. EXAMPLE: When 150 p.s.i. (10 bar) inlet pressure is
supplied to the motor of a 9:1 ratio pump it will develop a maximum of 1350 p.s.i.
(93 bar) fluid pressure (at no flow) -- as the fluid control is opened, the flow rate will
increase as the motor cycle rate increases to keep up with the demand.
AIR AND LUBE REQUIREMENTS
ACCESSORIES LIST
WARNING HAZARDOUS PRESSURE. Do not exceed maxi-
mum inlet air pressure of 150 psi (10 bar). Operating pump at
higher pressure may cause pump damage and/or personal in-
jury and/or property damage.
ITEM Description
1 Nipple (1/2 x 1-1/8)
4 Lubricator +
5 Basic Pump +
6 Material Hose
7 Air Hose
Qty Part No.
1
1
1
1
1
1
Y27-154-C
L36341-110
662420-B
624601-4
621501-3
75367
WARNING Refer to general information sheet for additional
safety precautions and important information.
• Excessive air pressure will shorten the life of the pump.
• Formaximumoperatingefficiency,thefollowingairsupplyspecifica-
tions should be maintained to this pump.
8 Swivel
+ SEE OPERATOR’S MANUAL
• AIR PRESSURE - Up to 150 P.S.I. (10 Bar)
• AIR FILTRATION - 50 micron
• LUBRICATED AIR SUPPLY
• AIR INLET SIZE - 1/2” NPTF
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
FAX(800) 892-6276
(800) 495-0276
© 2011
|